PLC programming

We design the control system, write the program and commission it on site. At the end you receive the source code, the I/O list and the operating instructions — so no single supplier has you locked in.

  • Automatic transfer control
  • Machine control
  • Building automation
  • Profinet · Modbus · OPC UA

When people get in touch

The jobs people
call us for

It is not always a new machine — often an existing process is missing its control system, or the one it has needs replacing.

A new machine or process is starting up

The mechanical side is ready, but the control program has not been written yet, and an operator interface is needed too.

  • A control concept built out from the process
  • I/O structure and architecture worked out
  • Program, HMI and commissioning from one hand

A manual operation needs automating

Today the process runs on manual switching, so it is slow and everything depends on the operator paying attention.

  • Manual and automatic modes side by side
  • Interlocks and unambiguous fault handling
  • An event log, so it is clear afterwards what happened

Transfer to a standby source is needed

Today a mains failure needs someone to step in, which takes time — and at night nobody is there.

  • Automatic transfer between the mains and the generator
  • Manual mode and interlocking for safe operation
  • Return transfer and logged events
A redundant PLC pair in a control cabinet, with a network switch and a row of I/O modules
A redundant PLC pair — both CPUs in RUN: if one drops out, the other carries the control on

What the work involves

What we do
in the assignment

1. Control concept and I/O structure

We go through the process and write down what the system has to do and when.

  • A functional description for each operating mode
  • I/O list, signal types, spare positions
  • Network architecture and communication protocols

2. Programming

A modular program structure, so it can still be extended and debugged later.

  • Mode handling, interlocks, alarm logic
  • Scaling of analogue signals, PID control
  • Recipe and parameter handling where it makes sense
  • Interfacing sensors and field signals
  • Motor starting logic: direct and star-delta, interlocking, thermal relay feedback
  • Drive control: VFD parameters, start and speed setpoint over fieldbus
  • Control of pneumatic and hydraulic actuators

3. Testing and commissioning

First on the bench, then on the real process. Commissioning happens on site.

  • A function-by-function check with a report
  • Every field signal and actuator measured through
  • Tuning under operating conditions

What you receive at handover

  • Functional description and an up-to-date I/O list
  • PLC and HMI program backup, source code included
  • Acceptance test report
  • Operating and maintenance instructions for the operators

These are not separately priced items but parts of the handover — at acceptance you can check them off one by one.

Platforms

What we work on

We fit in with what the client already has. If there is an installed base, we stay with it; if a new system is being built, we choose together.

  • Siemens
  • Schneider Electric
  • Omron
  • Beckhoff
  • Eaton
  • Mitsubishi

A controller from another make? Get in touch — we will tell you what we can take on. Write to us.

This list shows which platforms we take on work for. It does not mean a manufacturer partnership or an official certification.

Why SKY SOL

Why it is worth
calling us

Ten years in the field

The team has spent ten years in industrial environments: programming, commissioning, fault finding. We do not know machines from textbooks.

One engineer, start to finish

The same person surveys the job, writes the program and commissions it. You never have to explain the same thing twice, and nothing is lost in a handover.

The source code is yours

The program backup, the I/O list and the operating instructions are part of the handover, not a separately priced item. The system does not tie you to us.

We know this scale

We typically work up to 100 I/O: transfer controls, smaller plants, building automation. If a job is bigger than that, we say so up front.

Boundaries

Where our work
ends

Scope — what we do not take on

Clear boundaries

We do the design, the programming and the commissioning of the control system. The electrical design is produced by our design partner, and cabinet manufacturing and on-site installation are done by a specialist contractor. Technical coordination stays with us throughout.

Why this is good for you

You ask in one place, but every trade is done by whoever actually knows it. Responsibility and boundaries stay clearly separated throughout.

FAQ

What people
usually ask

How long does a PLC program take?

We give a deadline after the survey. It is not the signal count that decides, but whether there is a usable drawing, whether we can get to the machine, and when it can be shut down. The quote states the deadline we commit to — and what we need from you to meet it.

Which PLC platforms do you work on?

Siemens, Schneider Electric, Omron, Beckhoff, Eaton, Mitsubishi — and others on request. If there is an installed base, we fit in with it. If a new system is being built, we choose together.

Do I get the source code of the program?

Yes, source code included — and not as a separate line item. Without it the system would be tied to us, and we do not think that is fair.

What do you need in order to quote?

A few sentences about the process, an I/O list or at least an estimated signal count, any existing drawings, the platform and the deadline. If those are not available, we start with a survey.

Do you also do the on-site commissioning?

Yes. For us writing the program and commissioning it are one job. First we test the functions, then we tune the system on site on the real process — with an acceptance test at the end.

How big are the projects you take on?

Typically up to 100 I/O: transfer controls, machine control in smaller plants, building automation. A production line with several hundred I/O is not our profile — if that is what you have, we say so up front.

There is no documentation for the existing machine. Is that a problem?

Not an obstacle, just a separate phase. We survey the machine and write the I/O list and the missing descriptions — development starts from those. The survey results are yours even if you order the programming elsewhere.

Get a quote

Let us look at
the task

Describe in a few sentences what you need solved. We reply within one working day and tell you what we need in order to quote.

Phone+36 30 463 32 43 E-mailinfo@skysol.hu
Registered officeSKY SOL Kft. · Római körút 23.
6723 Szeged, Hungary — we work nationwide
What helps us quoteA description of the process, an I/O list or an estimated signal count, any existing wiring diagrams, the platform and the deadline.

To speed up the technical discussion, tell us the PLC/HMI type, the estimated I/O count, a short description of the task, the location and the deadline you need. You can send an I/O list or technical documentation to info@skysol.hu.

Fields marked are required. We reply within one working day. You can also write to us directly: info@skysol.hu